Permit: T07CM04746

Parcel: 13510150C

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
11/24/2008 REINFORCED MASONRY PRE-GROUT Approved
07/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
3RD LIFT/TOP OUT @ CMU DRIVE THRU PIERS - OK TO GROUT
07/23/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
9 EXTERIOR CMU PIERS ON WEST & SOUTH SIDES
TOP OUT AND 2 CMU PIERS FOR DRIVE THRU 2ND LIFT TO 8'8" OK TO GROUT
07/22/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TRASH ENCLOSURE TOP OUT @ 8'8"
9 CMU COLUMN PIERS ON SOUTH & WEST SIDE
FROM 4'8" TO 8'8" AND 2 DRIVE THRU CANOPY CMU COLUMNS 1ST LIFT FROM 0' TO 4'8"
07/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
9 - EXTERIOR CMU PIERS @ WEST & SOUTH OVERHANG FROM 0' TO 4'8" AND TRASH ENCLOSURE FROM 0' TO 4'
07/18/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOTE & BALE ENCLOSURES TOP OUT
07/16/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ TOTE & DALE ENCLOSURES
FROM 0' TO 8' 8" AFFE - OK TO GROUT
07/10/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BUILD OK
07/09/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP A/1-4; 4/A-E; E/3-4
07/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
G.L A.0 - E.0/1.0 - 4.0
16'8" - 20'8" OK
07/01/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
4TH LIFT TO 16 FOOT 8 INCH -- OK TO GROUT
06/27/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL FOUR PERIMETER CMU WALLS 3RD LIFT - OK TO GROUT
SPECIAL INSPECTION PERFORMED
06/26/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
06/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
2ND LIFT TO 8 FOOT 8 INCH ON ALL FOUR EXTERIOR
CMU WALLS -- OK TO GROUT
06/23/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT TO 4 FOOT AFF @ WEST CMU WALL
06/20/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT FROM TOP OF STEM TO 4 FEET @ NORTH, SOUTH, EAST - EXTERIOR CMU WALLS
06/18/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
STEM OK