Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM04734
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/06/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/04/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE PAGE 5-1.2 FOR A.B. SCHEDULE ALL EXT/INTERIOR BEARING 2) MOVE PEX HALL CAN 1ST FLOOR 3) MISSING TOP PLATE HALL CLOSET 1ST FLOOR NEXT TO KIT./BATH 4) NEED H20 IN SHOWER PAN 2ND FLOOR 5) BACKING AT SHOWER, 2ND FLOOR (SIDES, VERTICAL) 6) OVERSPAN STUD, TUB/SHEAR 2ND FLOOR 7) FRONT BEDROOM 2ND FLOOR, ROMEX SHEATH, SKINED, RECEPT. EAST WALL, WRAP WITH TAPE 8) BLOCK UNDER HIP AT TOP OF FLAT TRUSS FRONT, HIP AT RIDGE 9) CHECK HANGER LUS26-HJ08 TRUSS |