Permit: T07CM04723

Parcel: 140252400

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/28/2008 FRAMING Approved IVRS - Inspection :*
04/25/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH NOTES 1 & 2 FROM PREVIOUS
04/22/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CUT NAIL ALL BOTTOM PLATES
2. BANG PLATE ALL ROMEX THROUGHOUT, ANY WIRE CLOSER THAN 1 1/4" TO EDGE
3. NAILS IN HANGERS AT FRONT WALL TO BE .164d 16d
4. BLK ALL MECH. DUCTS
5. DAMAGED AMER FLEX INSULATION, AC LINES
04/15/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER PLUMBER
04/09/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
03/13/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE STUCCO MESH AND ALL TRADES PRIOR TO FRAME INSPECTION
03/07/2008 FRAMING Cancelled IVRS - RI canceled