Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 07/18/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ROUGH SOIL FOR NEW SINK OK |
|
| 07/15/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK |
|
| 06/20/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 3/4" WATER LINES PER REDLINES OK SUBJECT TO REVISED PLAN |
|
| 06/19/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CONNECT 3/4 TO 1" AS SHOWN ON UNAPPROVED PLANS REDLINE APP PLANS, LEAVE CONNECTION EXPOSED APPROVAL SUBJECT TO APPROVED PLAN REV. |
|
| 06/18/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1/2" WATER LINES TO NEW FIXTURE SECURE PIPING IN WALL ISOLATE CW FROM METAL DUCT REMOVE EXCESS FLUX W/DAMP RAG REDLINE CHANGE ON APPROVED PLAN NOTE: ADDING FIXTURES MAY CHANGE PIPE SIZING REQUIREMENTS |
|
| 05/28/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - PROTECT COPPER FROM STUCCO - OK TO COVER WALLS - NEED TO SEE CLOSET FLANGES AND PLAN REVISIONS PREVIOUSLY NOTED. |
|
| 05/22/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV TEST OK 2) TEST ON WATER OK 3) PROVIDE PIPE INSULATION AND SAFETY PLATES |
|
| 05/21/2008 | PLUMBING - INTERMEDIATE | Cancelled | ||
| 03/20/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1 1/2" TYPE L COPPER W/BRAZED JOINTS INSTALLED INTO SLAB |