Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM04651
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/19/2008 | FRAMING | Approved | ||
04/01/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* - NO PLANS OR PERMIT - GAS LINE STILL 1/2" - HTT 16's FRONT OF HOUSE? |
|
03/28/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLATFORM FOR FURNACE, H20 HTR ? (REQUIRED) 2) PLAN CALLS FOR 3/4" DIAMETER PIPE (GAS) TO RANGE. NEED PLAN BTU RATINGS FOR APPLIANCES 3) PROTECT PEX FROM HEAT DBL LAV, LIGHT CANS (WOOD) 4) MISSING TWO HTT16 H.D.'S AT FRONT BEDROOM. ARE THERE TWO ON EACH SIDE ? |
|
03/25/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |