Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - ABOVE CEILING
Permit Number - T07CM04638
Inspection Description - MECHANICAL - ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/18/2009 | MECHANICAL - ABOVE CEILING | Approved | IVRS - Inspection :* | |
08/06/2009 | MECHANICAL - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* | |
07/30/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* OK FOR CIELING TILES 1ST AND 2ND FLEERS WITH THE EXCEPTION OF AREAS WITH LINEAR DIFFUSERS, INSULATE LINEAR DIFFUSERS TO A MIN. R 4.2 HURIZ. B-VENT NOT TO EXCEED 75 DEGREES TOTAL VERT. RISE AND NOT LESS THAN 60 DEGREES |
|
07/02/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) OK FOR SHEETROCK ELEVATOR LOBBY 1ST AND 2ND FLOOR |
|
07/01/2009 | MECHANICAL - ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DUCT IS TIED TO EMT WITH BAILING WIRE 2) DUCT NOT WRAPPED 3) BOOT NOT SEALED OR WRAPPED |
|
06/24/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* PROVIDE ACCESS TO DISCONNECT PER NEC |
|
05/18/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* NO COMBUSTIBLE MATERIAL ALLOWED IN PLENUM CEILING OK FOR RESTROOMS 1ST FLR ROCK |
|
05/13/2009 | MECHANICAL - ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 1" CLEARANCE TO COMBUSTIBLE ON ALL B-VENT 2) SEAL ALL DUCT JOINTS INCLUDING RISERS 3) COMPLETE DUCT SYSTEMS 4) COMPLETE LIST DATED 5/6/09 |
|
05/07/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
05/06/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1. TU-14 PROVIDE PROPER ACCESS 2. MED. PRESSURE DUCT TO TU-13 NOT PROPERLY SUPPORTED - SUPPORT ALL DUCT PER IMC AND SMACNA 3. TU-9 RELOCATE UNIT FROM PLANE OF WALL & SEAL ALL DUCT 4. SEAL JOINTS AT TU-8 5. SEAL ALL DUCT JOINTS 6. VERIFY LOCATIONS OF SUPPLY AND EXHAUST GRILLS IN RESTROOMS 7. BRANCH DUCTS ARE NOT TO BE SUPPORTED BY BRANCH TAPS 8. OK TO INSTALL ALL GRID |
|
02/25/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
02/24/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
02/24/2009 | MECHANICAL - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* |