Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T07CM04638
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2009 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 04/27/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STORAGE PAD |
|
| 04/08/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 03/31/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 03/26/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 LIGHT POLE BASES NORTHWEST CORNER |
|
| 03/16/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* BATTERY PIT OK |
|
| 03/10/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 LIGHT POLE BASES |
|
| 03/06/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 5 LIGHT POLE BASES |
|
| 02/23/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 02/18/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* WEST SCREEN WALL AT TRANSITION |
|
| 02/17/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* WEST SCREEN WALL NORTH OF FUEL PUMPS |
|
| 02/04/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 110' WEST SCREEN WALL | |
| 01/30/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 80' SCREEN WALL WEST SIDE |
|
| 01/27/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* TRANSFORMER PAD |
|
| 01/26/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 01/22/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 01/16/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* NORTH SCREEN WALL WEST END |
|
| 01/13/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 01/12/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SCREEN WALL 100' EAST TO WEST |
|
| 12/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 55' NORTH SCREEN WALL |
|
| 12/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 12/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 12/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 160' NORTH SCREEN WALL |
|
| 12/11/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 200' SCREEN WALL FOOTER NORTH SIDE |
|
| 11/21/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
| 11/21/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* NO PROGRESS |
|
| 11/06/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* EAST SCREEN NORTH END G.L 1/A-F |
|
| 11/04/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 11/03/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 10/31/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SPECIAL INSPECTIONS ACCEPTED HAVE AVAILABLE FOR INSPECTOR NEXT WEEK WAITING ON RFI FOR NON-COMPLIANT ISSUES |
|
| 10/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 10/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. 6 EACH F6 FOOTINGS LINE 6 LINE 8/G-J OK 2. F2 FOOTING LINE A/1-7; LINE 1/A-B OK 3. VERTS FOR SHEAR @ B/7 NOT INSTALLED |
|
| 10/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
| 10/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 10/21/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* G.L 7.0/B.1-F.6, F.0/1.0-11.0, 11.0/F.0-J.3 |
|
| 10/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* ELEVATOR PIT |
|
| 10/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 50' SOUTH SCREEN WALL | |
| 10/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 10/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 95' SOUTH END OF SCREEN WALL |
|
| 10/03/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* ELEVATOR PIT, 85' SCREEN WALL EAST TO WEST |
|
| 10/01/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 155' EAST SCREEN WALL |
|
| 09/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 09/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GL 1, 2, 3 - C |
|
| 09/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 09/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 60' SCREEN WALL EAST SIDE OF PROPERTY |
|
| 09/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 60' SCREEN WALL ON EAST SIDE OF PROPERTY |
|
| 09/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 40' OF SCREEN WALL EAST SIDE OF PROPERTY |
|
| 09/05/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 09/04/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 40' SCREEN WALL EAST SIDE OF PROPERTY |
|
| 08/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 INTERIOR FOOTERS |
|
| 08/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 08/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 08/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL 100' OF RETAINING WALL EAST END OF PROPERTY |
|
| 08/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* EXCLUDES ELEVATOR FOOTER |
|
| 07/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* G.L K-P-6-8, 11-4-R-S 20 TOTAL COLUMN FOOTERS |
|
| 07/27/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 195' EAST RETAINING WALL NORTH OF EXISTING CHANNEL |
|
| 07/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* LOWER LEVEL G.L B-D - 1-6 GL J-K - 2-11 |
|
| 07/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 07/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
| 07/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F-3 LINE 11/1-Q F-2 LINE Q/11-13 F-3 LINE T/2-13 (NEEDS #6 VERTS @ SHEAR PLASTERS) F-1 FOOTING 11-13/Q-R AREA |
|
| 07/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F2 - FOOTING T/5.5-2 F10 - LINE 2/P-T F2 - Q/2-3 F3 - LINE 3/K-Q |
|
| 07/11/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED |