Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/25/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
| 03/10/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER LARRY |
|
| 02/26/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WALL SCHEDULE CALLS FOR W1-2 X 6 WALLS ON SOUTH EXT WALL NOT 2 X 4 FRAMING 2) MISSING 2 X BLOCKING ON LEDGERS PER DETAIL 1/SD1 ON BEARING WALLS 3) UNABLE TO VERIFY ST22 STRAP AND A34 4 PLACES PER DETAIL 15/SD1 GARAGE 4) MISSING PAHD 42 AT GARAGE 5) MISSING A.34 PER DETAIL 7/SD1 6) MISSING 4 X 6 POST ANCHOR PER DETAIL 18/SD1 AT DOWNSTAIRS BATH 7) DECK NAILING 2ND FLOOR NOT PER PLAN |