Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/07/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/03/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* COMPLETE ALL ITEMS ON 6/27/08 INSPECTION AND THEN CALL IN FOR INSPECTION FAILURE TO DO SO WILL RESULT IN REINSPECTION FEE. |
|
| 06/27/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PIPE SANITIZE COMPARTMENT INDIRECTLY TO FS WITHOUT TRAP OR AAV, BUT DO PROVIDE AN AIR GAP. - PROVIDE A GRATE ON FS - CLIP NEW SINK - SECURE HAND SINK, REMOVE HOSE THREADS AND INSTALL AERATOR - NOTE 19 ON PLANS SAYS TO INSTALL A NEW WH W/RELIEF DRAIN TO EXTERIOR |
|
| 06/19/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* HOLD PLACED ON PERMIT SEE BETH GRANT AT PERMIT COUNTER |