Permit: T07CM04567

Parcel: 14117007Q

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM04567

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/09/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/27/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
03/26/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
03/24/2009 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
DRAINAGE TO INTERCEPTOR TO HAVE 1/4" PER FOOT FALL MINIMUM. THERE CAN BE NO SYSTEM VENT BETWEEN THE FLOW CONTROL VENT AND THE INTERCEPTOR. PROVIDE A FULL SIZE UPPER TERMINAL CLEANOUT ON GREASE DRAINAGE
VENT FROM INTERCEPTOR TO BE MINIMUM TAKEN OFF AT CENTER LINE OF DRAINAGE FLOW AND HAVE RISE TO POINT OF VENT CONNECTION
07/23/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
POST YOUR SUITE # ON THIS BLD.
FAILURE TO DO SO WILL RESULT IN NO INSPECTION
SANITARY DRAINAGE THRU BLD. TO CONNECTION TO EXISTING BUILDING DRAIN WATER TEST OK
PIPE WRAPS ON SANITARY OK
RECALL FOR GREASE DRAINAGE & GREASE TRAP
07/22/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
POST YOUR SUITE # ON THIS BUILDING FOR FUTURE INSPECTIONS - WHERE IS YOUR APPROVED HEALTH DEPT. PLAN?

1. INSTALL PIPING PER APPROVED PLAN OR PROVIDE REDLINES ON SITE AT TIME OF INSPECTION
2. HORIZONTAL VENTING BELOW FLOOD RIM OF FIXTURE CANNOT BE REVENTED TOGETHER
3. 3" FLOOR SINK REQUIRE 3" TRAPS & TAILPIECES (P-6 AT 3-COMP SINK LOCATION PLAN SPEC IS 2")
4. SOILS IN DITCH FOR WATER TEST TO BE FREE OF MUD