Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 02/08/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRIP LEG GAS LINE AT WATER HEATER 2) PROVIDE HIGH/LOW COMBUSTION RELIEF TO EXTERIOR 100 CUBIC INCHES EACH 3) PROVIDE ACCESS TO ATTIC 4) PROVIDE HIGH/LOW COMBUSTION TO MECHANICAL FURNACE ROOM |
|
| 01/11/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS 7:50 AM |
|
| 12/21/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH #1 & #2 BELOW AND SECURE B VENT AT FURNACE 2) GAS UNITS ARE ON AT THIS TIME ENERGIZED BY APPLE PLUMBING |
|
| 12/14/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) B-VENT SHALL BE 1" CLEARANCE FROM COMBUSTIBLE AT FURNACE AND WATER HEATER 2) COMB AND RELIEF REQUIRED AT FURNACE COMPARTMENT 3) EXPOSED ROMEX WIRE SHALL BE PROTECTED 4) BUBBLE COVER REQUIRED AT EXTERIOR OUTLET |