Permit: T07CM04557

Parcel: 129024180


Addresses:

2710 E MALVERN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/17/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
02/08/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRIP LEG GAS LINE AT WATER HEATER
2) PROVIDE HIGH/LOW COMBUSTION RELIEF TO EXTERIOR 100 CUBIC INCHES EACH
3) PROVIDE ACCESS TO ATTIC
4) PROVIDE HIGH/LOW COMBUSTION TO MECHANICAL FURNACE ROOM
01/11/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS 7:50 AM
12/21/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH #1 & #2 BELOW AND SECURE B VENT AT FURNACE
2) GAS UNITS ARE ON AT THIS TIME ENERGIZED BY APPLE PLUMBING
12/14/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) B-VENT SHALL BE 1" CLEARANCE FROM COMBUSTIBLE AT FURNACE AND WATER HEATER
2) COMB AND RELIEF REQUIRED AT FURNACE COMPARTMENT
3) EXPOSED ROMEX WIRE SHALL BE PROTECTED
4) BUBBLE COVER REQUIRED AT EXTERIOR OUTLET