Permit: T07CM04537

Parcel: 141353650

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM04537

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/05/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/22/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
MOVING GARAGE WALL
CALL WHEN READY
04/11/2008 EXT METAL CLIPS/EXT SHEATHING Denied 1) ENGINEER FIX FOR GARAGE STEM WALL
2) BEARING WALLS OVERSPANED WHERE DRYER DUCT IS
3) BEARING WALL OF KITCHEN OVERSPANED WITH CUT STUDS
4) DRAFT STOP FLOOR TRUSSES MAXIMUM 1000 DIAMETER
5) NAIL FHA STRAPS ON BEARING WALLS TO CODE
6) BANG PLATES NEEDED OVER GLYCOL LINES IN GARAGE
7) DRAFT STOP TUBS FROM 1ST TO 2ND FLOOR
8) ANCHORS NEEDED IN HOLDOWNS
9) PROPER NAILING ON FHA STRAPS NORTH EAST CORNER 1ST FLOOR
10) 3RD INSPECTION-REFEE IF NOT READY NEXT TIME
11) STOPPED INSPECTION
04/10/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ENGINEERING FROM PRESVIOUS INSPECTION
2) TO MANY ITEMS, NOT DONE
03/25/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NOTE: BEARING AT GARAGE STEM, NEED CONCRETE REPAIR ENGINEERING
03/24/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection STILL SHEATHING