Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/08/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* ONLY ONE SLIP NUT ALLOWED ON OUTLET SIDE OF P-TRAP T&P RELIEF DRAIN OK |
|
| 04/04/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. T&P RELIEF DRAIN TO BE FULL SIZE 2. PRESSURE FITTINGS NOT PERMITTED ON DWV HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP |