Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM04521

Parcel: 118200910


Addresses:

1508 S 9TH AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/16/2008 FRAMING Approved IVRS - Inspection :*
05/15/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE ENGINEERED FIX TRUSS REPAIR GARAGE & ENTRY
PROVIDE WATER TEST ABS POTABLE WATER OK
FIRE STOP OVER KNOTCH TOP PLATE LAUNDRY VENT
REPAIR OVER KNOTCH DOUBLE TOP PLATE BEDROOM 2
SEAL WEEP SCREEDS INTERIOR
05/14/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE LATHE
04/28/2008 FRAMING Not ready for Inspection IVRS - Inspection :*