Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/19/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS OR PERMITS ON SITE |
|
| 03/04/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING OSB SHEAR AT FRONT OF GARAGE 2) DETAIL 2/10 ON END TRUSS NOT PER PLAN 3) WEB PLATE NAILERS ON TRUSS HAVE BEEN BENT AN PULLED BACK 4) MISSING A35 CLIPS ON 2 X BLOCKING PER DETAIL 1/10 5) STOPPED INSPECTION AT THIS TIME 6) FOLLOW DETAILS, FAILURE TO DO SO WILL RESULT IN A REFEE NEXT TIME |
|
| 02/28/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO FOLLOW ALL APPROVED PLAN/DETAILS OR REVISE WITH CITY APPROVALS |
|
| 02/25/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED BY CHERYL |