Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM04495
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/17/2008 | FRAMING | Approved | IVRS - Inspection :* | |
01/15/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO SEAL ALL OPENINGS IN STUCCO MESH (LIGHTS AND RECEPTACLES) 2) ELECTRIC RECEPTACLES BOXES NEED TO BE IN PLACE WITH WIRE IN THEM 3) BEARING WALL WITH WINDOW REQUIRES 2 TRIMMERS ON EACH SIDE 4) STAPLING OF FOAM INSULATION NEEDS TO BE TO A 2 X 4 STUD NOT JUST OSB |