Permit: T07CM04467

Parcel: 122080330


Addresses:

4253 E NORTH ST

Inspection Status: Denied

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/04/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/28/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PAINT PVC EXPOSED AT EXTERIORS
2) PROVIDE BACKFLOW PREVENTION AT EXT. HOSE BIBS
3) NEED TO CALL IN FOR ELECTRIC UPGRADE INSPECTION #T08EL00290
4) PROVIDE ANTI-SHORT BUSHINGS AT EMT/CONDUCTORS
5) SEPERATE NEUTRALS GROUNDING CONDUCTORS AT SUB-PANEL
6) NEUTRAL CANNOT TERMINATE INTO BREAKERS ?
7) RE-IDENTIFY IF IT IS AN UNDERGROUND CONDUCTOR ?
8) SEPERATE UNDERGROUNDED CONDUCTORS AT SUB PANEL (1) PER DISCONNECT (BREAKER)
9) SECURE SUB PANEL TO FRAMING PROPERLY
10) MISSING SMOKE DETECTORS AT BEDROOMS
11) NEED TO HIRE A LICENSED ELECTRICAL AND PLUMBING CONTRACTOR TO BRING BLDG UP TO CODE
12) TO MANY ITEMS TO LIST/INSPECTION STOPPED
13) WARNING: A RE-INSPECTION FEE WILL APPLY IF NOT IN COMPLIANCE AT NEXT RECALL
02/25/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PLANS/PERMIT ON SITE
2) EXPOSE GROUND RODS
3) SECURE GROUNDING ELECTRODE CONDUCTOR AT SERVICE PANEL/COULD NOT OPEN SERVICE PANEL ?
01/25/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 UNITS ON THIS PROPERTY. APPEARS TO HAVE SOME ADDITIONS DONE WITHOUT INSPECTIONS. PROPERTY WILL NEED TO BE RESEARCHED FOR PROPER PERMITS
2) SERVICE PANEL NEEDS TO BE UPGRADED
3) TO MANY VIOLATIONS TO NOTE
4) CUT WIRES AT EXTERIOR
5) MISSING ELECTRIC FIXTURES
6) TEP HAD PAD LOCKED SERVICE PANEL (BREAKER SIDE)
7) TWO ELECTRIC FURNACES INSTALLED, NO DISCONNECTS, POWER SERVICE RUN DIRECTLY INTO FURN. CABINET
8) SUB PANEL ADDED COULD ONLY FIND ONE, BREAKERS IN SERVICE NOT LABELED OF ALL DIFFERENT BRANDS, SOME AMPERAGE ON SWITCH WORN OFF
9) 20' + ADDITION ADDED TO REAR WITH 2ND KITCHEN
10) GAS LINE IN ONE FURNACE ROOM NOT CAPPED
11) LAUNDRY ROOM LOOKS LIKE AN ADDITION
12) SUB PANEL IN LAUNDRY NOT WIRED CORRECTLY, UNABLE TO VERIFY WHICH BREAKER FEEDS SUB-PANEL
13) STOPPED INSPECTION
11/28/2007 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PANEL NEEDS TO BE ACCESSIBLE
2) FIXTURES AND BARE WIRES ON NORTH SIDE OF HOUSE