Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/04/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/28/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PAINT PVC EXPOSED AT EXTERIORS 2) PROVIDE BACKFLOW PREVENTION AT EXT. HOSE BIBS 3) NEED TO CALL IN FOR ELECTRIC UPGRADE INSPECTION #T08EL00290 4) PROVIDE ANTI-SHORT BUSHINGS AT EMT/CONDUCTORS 5) SEPERATE NEUTRALS GROUNDING CONDUCTORS AT SUB-PANEL 6) NEUTRAL CANNOT TERMINATE INTO BREAKERS ? 7) RE-IDENTIFY IF IT IS AN UNDERGROUND CONDUCTOR ? 8) SEPERATE UNDERGROUNDED CONDUCTORS AT SUB PANEL (1) PER DISCONNECT (BREAKER) 9) SECURE SUB PANEL TO FRAMING PROPERLY 10) MISSING SMOKE DETECTORS AT BEDROOMS 11) NEED TO HIRE A LICENSED ELECTRICAL AND PLUMBING CONTRACTOR TO BRING BLDG UP TO CODE 12) TO MANY ITEMS TO LIST/INSPECTION STOPPED 13) WARNING: A RE-INSPECTION FEE WILL APPLY IF NOT IN COMPLIANCE AT NEXT RECALL |
|
| 02/25/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PLANS/PERMIT ON SITE 2) EXPOSE GROUND RODS 3) SECURE GROUNDING ELECTRODE CONDUCTOR AT SERVICE PANEL/COULD NOT OPEN SERVICE PANEL ? |
|
| 01/25/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 UNITS ON THIS PROPERTY. APPEARS TO HAVE SOME ADDITIONS DONE WITHOUT INSPECTIONS. PROPERTY WILL NEED TO BE RESEARCHED FOR PROPER PERMITS 2) SERVICE PANEL NEEDS TO BE UPGRADED 3) TO MANY VIOLATIONS TO NOTE 4) CUT WIRES AT EXTERIOR 5) MISSING ELECTRIC FIXTURES 6) TEP HAD PAD LOCKED SERVICE PANEL (BREAKER SIDE) 7) TWO ELECTRIC FURNACES INSTALLED, NO DISCONNECTS, POWER SERVICE RUN DIRECTLY INTO FURN. CABINET 8) SUB PANEL ADDED COULD ONLY FIND ONE, BREAKERS IN SERVICE NOT LABELED OF ALL DIFFERENT BRANDS, SOME AMPERAGE ON SWITCH WORN OFF 9) 20' + ADDITION ADDED TO REAR WITH 2ND KITCHEN 10) GAS LINE IN ONE FURNACE ROOM NOT CAPPED 11) LAUNDRY ROOM LOOKS LIKE AN ADDITION 12) SUB PANEL IN LAUNDRY NOT WIRED CORRECTLY, UNABLE TO VERIFY WHICH BREAKER FEEDS SUB-PANEL 13) STOPPED INSPECTION |
|
| 11/28/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PANEL NEEDS TO BE ACCESSIBLE 2) FIXTURES AND BARE WIRES ON NORTH SIDE OF HOUSE |