Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* RECEIVED BACTERIA REPORT |
|
| 09/15/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* INSTALL CLEANOUTS PER PLAN FOR URINALS AS REQUESTED ON 8/7/08 NOTE: IN THE FUTURE YOUR BACTERIA REPORT NEEDS TO HAVE THE PROJECT ADDRESS ON IT |
|
| 09/09/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/28/2008 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled | |
| 08/07/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE TESTING ON DWV THRU ROOF OR INSPECTION HISTORY SHOWING IT HAS BEEN DONE 2) PROVIDE CLEANOUTS PER PLAN AND 2006 UPC REQUIREMENTS 3) PROVIDE APPROVED COUPLINGS FOR TRANSITION FROM PLASTIC TO PLASTIC 4) SUPPORT AND SECURE VENT SYSTEM PER 2006 UPC 5) MAKE ALL FIXTURE WATER TIGHT 6) PROVIDE BACTERIA REPORT FOR POTABLE WATER 7) PAINT VENT TERMINATION THRU ROOF |