Inspection Status: Approved
Inspection History: ENGINEERING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/29/2008 |
ENGINEERING - FINAL |
|
Approved |
|
| 01/31/2008 |
ENGINEERING - FINAL |
|
Cancelled |
SPOKE WITH TERRY (CONTRACTOR 440-7580), HC ACCESS RAMP NOT 1:12 SLOPE PER ADA AND SURFACE NOT CONCRETE PER THE APPROVED PLANS. |
| 01/30/2008 |
ENGINEERING - FINAL |
|
Denied |
RAMP DOES NOT MEET 1:12 (8.3%) SLOPE REQUIRED BY ADAAG. FURTHERMORE; PEOPLE WHO HAVE DIFFICULTY WALKING OR MAINTAINING BALANCE OR WHO USE CRUTCHES, CANES, OR WALKERS, AND THOSE WITH RESTRICTED GAITS ARE PARTICULARLY SENSITIVE TO SLIPPING AND TRIPPING HAZARDS. FOR SUCH PEOPLE, A STABLE AND REQULAR SURFACE IS NECCESSARY FOR SAFE WALKING. WHEEL CHAIRS CAN BE PROPELLED MOST EASILY ON SURFACES THAT ARE HARD, STABLE, AND REQULAR. SOFT LOOSE SURFACES SUCH AS SHAG CARPET, LOOSE SAND OR GRAVEL, WET CLAY AND IRREGULAR SURFACES SUCH AS COBBLESTONES CAN SIGNIFICANTLY IMPEDE WHEELCHAIR MOVEMENT AS PER ADAAG A44.5.1. |