Permit: T07CM04451

Parcel: 141196350

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/31/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/28/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) STILL WORKING
01/23/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) END WALLS USE H2.5 TO TIE TO ROOF NOT A3.5
2) NEED BETTER BLOCKING ? FIREPLACE AND AT ENDS OF ROOF THAT WILL ATTACH TO PARAPET (WALL TAPERS) INTO TILE. NO SUPPORT FOR ROOF OSB
3) TIE COLUMN BOTTOM PLATES TO STUDS
01/22/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED HTT HD AT WEST END
2) BLOCK UNDER OSB AROUND FIREPLACE
3) INSTALL OSB FOR H2.5 NAILERS AT TJI BEARING
4) H2.5 AT EACH END WALL 48" ON CENTER