Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/31/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/28/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) STILL WORKING |
|
| 01/23/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) END WALLS USE H2.5 TO TIE TO ROOF NOT A3.5 2) NEED BETTER BLOCKING ? FIREPLACE AND AT ENDS OF ROOF THAT WILL ATTACH TO PARAPET (WALL TAPERS) INTO TILE. NO SUPPORT FOR ROOF OSB 3) TIE COLUMN BOTTOM PLATES TO STUDS |
|