Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/28/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/07/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK SOFFITS |
|
| 04/04/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK STOCKROOM WALLS, HARD LIDS IN FITTING & BATHROOMS |
|
| 04/01/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK NORTH & SOUTH FRONT WALLS ROUGH |
|
| 03/31/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SUPPORT CONDUIT WITHIN 3' OF TERMINATION PER NEC 2. MC CABLE MUST BE 1 1/4" MIN. BEHIND STUD FACE TO PROTECT FROM SCREWS. SUPPORT WITHIN 12" OF BOX OR TERMINATIONS, AND AT 6' INTERVALS, USE STRAPS LISTED FOR MC SUPPORT, 1/2" CONDUIT STRAPS NOT APPROVED PER NEC 3. PROVIDE LETTER FROM ARCH. FOR APPROVAL TO USE MC CABLE |