Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM04438
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/31/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/27/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BOLTS STILL NEEDED IN HOLDOWN NORTH CORNER 2) OVER SPAN OF STUDS IN UPSTAIRS BATH 3) SAFETY GLAZING NEEDED IN STAIRWELL 4) FILL SHOWER PAN UPSTAIR 5) BANG PLATE KITCHEN PONY WALL FOR PEX |
|
03/21/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) STILL WORKING |
|
03/17/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REVISION NEEDED FOR TGA TRUSS RAFTER INSTEAD OF 5 1/2 X 19.5 GLUE LAMB BEAM 2) NAIL OFF 2ND FLOOR 3) ROOF FRAMING DETAIL FOR ABOVE STAIRWAY, B-ELEVATION=HIP ROOF |
|
03/13/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CORRECTIONS OK |
|
03/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER STEWART |
|
02/26/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADD 3 2 X 6 STUDS UNDER PT. LOAD FROM ROOF BEAM TO KITCHEN SHEAR 2) NEED CONVERSION GLU LAM HEADERS 1ST FLOOR FROM NOMINAL 3-2 X 12'S 3) NEED MTT28 B H.D.'S EACH SIDE OF GARAGE 4) MISSING WIND BRACING 2ND FLOOR 5) #8 STRAP H.D. DBL CS14 <8> SIX LOCATIONS 6) SHEAR WALL #2 1ST FLOOR EAST BLOCKED 7) #6 REAR SHEAR 4-12 NAILING 8) #7 SHEARWALL 5/8 DIAMETER AB'S 16" ON CENTER 9) HD8A REAR WALL WAS MARKED TO GO IN AT CORNER 10) NAIL ALL VERT STUDS ATTACHED TO PA'S AND HD'S 11) MAKE SURE HTU 26-2 IS THE RIGHT HANGER IN LIEU OF GLT3 12) STOPPED INSPECTION |
|
02/25/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER SUPER |