Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07CM04407
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/03/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
11/29/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. FIXTURES TO HAVE PROPER ROMEX CONNECTOR OR J-BOX 2. NEED SINGLE RECEPTACLE OR GFI PROTECTION AT WASHER 3. J-BOX BUSHING TO GO INTO BOX - NOT SIDING *THERE WILL BE A FEE IF NOT CORRECT NEXT INSPECTION |
|
11/28/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. IDENTIFY CKTS 2. NEED BREAKER BLANKS 3. SHEETMETAL SCREWS NOT ALLOWED FOR GROUND LUG REMOVE PAINT UNDER LUG 4. RECEPTACLES SHOW OPEN GROUND |
|
11/21/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CKT'S TO PROPERLY CONNECT TO INDIVIDUAL BREAKERS 2. IDENTIFY CKT'S ON PANEL DIRECTORIES 3. MULTI-WIRE BRANCH CKTS TO TERMINATE ON SEPARATE PHASES 4. NEED PROPERLY SIZE EQUIPMENT GROUND RAN WITH NEW CKTS 5. GROUND J-BOXES 6. NEED ROMEX CONNECTORS FOR ENTRY INTO J-BOXES 7. PROVIDE SINGLE RECEPTACLE FOR WASHER, GFI RECEPTACLE FOR DUPLEX |