Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/16/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/08/2008 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 01/03/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) AT KIT SINK USE SANITARY FITTINGS NOT VENT 90S, AIR ADMITTANCE VALVE TO BE INSIDE KIT CABINET NOT INSIDE WALL-INSTALL CLEANOUT 2) LOWER ALL INSULATION DOWN TO DRYWALL PAPER BACKING IS FLAMABLE, NO FLAME SPREAD RATING 3) DON'T USE VENT 90 DEGREE ON DRAINAGE PIPES 4) CLOSET LIGHTS 6" TO SHELF FOR FLOURESCENT, RECESSED AND ? INCANDESCENT TO SHELF 5) SHOWER WAS EXISTING 6) WASHER HAD EXISTING 1 1/2" DRAIN, USE 1 1/2" PIPE FOR DRAINAGE |
|
| 12/31/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) GATES LOCKED-NO ACCESS 9:40 AM |