Permit: T07CM04394

Parcel: 122010740

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/13/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
12/11/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CO BETWEEN BOWLS: TOM CAP NTO CORRECTLY INSTALLED
WASHER CONNECTIONS REQUIRE HAMMER ARRESTORS
ONLY ONE SLIP NUT ALLOWED DN STREAM OF P TRAP
EXPOSE CLEAN OUT AT D.F
CANNOT USE SHAMPOO BOWLS UNTIL VACUUM BREAKERS ARE INSTALLED.
12/10/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE ACCESS
PATCH HOLE IN REAR WALL
MAKE CLEANOUTS GAS TIGHT W/THREAD SEALANT
12/07/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE CORRECT BACKFLOW PROTECTION FOR SPRAYERS AT SHAMPOO SINKS OR LISTING SHOOT
2. PROVIDE MACHINE SCREWS GOING INTO FACTORY TAP OF CLEANOUT PLUGS, TO PREVENT UNSANITARY CONDITIONS.
11/23/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CHECK FOR HW & CW ORIENTATION AT BACK TO BACK SINKS