Inspection History: ELECTRIC - ABOVE CEILING

Date Description Inspector Results Comments
12/04/2007 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection :*
11/29/2007 ELECTRIC - ABOVE CEILING Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
11/28/2007 ELECTRIC - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL TIE WIRE TO LIGHTING FIXTURES
2. LIGHTING FIXTURES TO BE SECURED TO GRID
3. SEAL OPEN KNOCKOUTS IN JUNCTION BOXES
4. TIE WIRES USED FOR SUPPORT OF MC CABLES TO BE SECURED AT BOTH ENDS