Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM04385
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
08/20/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* USE APPROVED LINING MATERIALS W/MESH AROUND CLAMPING RING AND SEAL TO 3" ABV FLOOD LEVEL |
|
08/07/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PM INSPECTION REQUESTED 2) NO ACCESS DUE TO GLUE ON FLOOR |
|
07/31/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK SHOWER PAN LINERS SHALL BE INSTALLED AND INSPECTED PER UPC INSTALLATION STANDARDS #4 PG. 313 HANDOUT PROVIDED |
|
04/10/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CORRECTION ON VENT OK NEED TO SEE CLOSET FLANGES AND ABV CEILING JUST PRIOR TO CEILING GRIDS |
|
04/08/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* YOU STILL HAVE A 1/4 BEND ON A VENT WHICH IS BELOW THE FLOOD LEVEL OF THE FIXTURE |
|
04/04/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - SWEEP REQUIRED ON BELOW FLOOD LEVEL VENT - TEST ON DWV LEVEL 3 TO CEILING HEIGHT NORTH OF HALL - TEST ON VENTS TO L4 ON SOUTH SIDE OK - OK TO COVER WALLS |
|
04/02/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - LEAK ON VENT T 2ND LEVEL - TEST ON DWV ON SOUTH SIDE OF HALL FROM CEILING OF L2 TO CEILING OF L3 - PROVIDE TEST ON ABV CEILING REVENTS - NORTH OF HALL 1/4 BENDS ON DRAINS, CARRIERS NOT SECURED - NOTE: REINSPECTION FEES MAY BE ASSESSED IF CONTRACTOR FAILS TO CORRECT ISSUES. |
|
03/28/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* COMPLY WITH PAST NOTES, PROVIDE WATER TIGHT TEST ON DWV, SUPPORT & SECURE LAV CARRIERS |
|
03/26/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* WATER ON PIPES SLOPE SUPPORTS SWEEP 90 DEG'S ON DRAIN ARMS IP HANGERS ON CU BRASS PLUGS ON FUTURE VALVE LOCATIONS |
|
02/28/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* LEVEL 3 COPPER PRESSURE TEST OK INSULATE PER SPEC. PROVIDE NECESSARY CLEARANCE SUPPORT PIPING, CLAMPS, SECURE VERTICAL DROPS REMOVE ANY EXCESS FLUX BE SURE INSTALLERS ARE REAMING ALL JOINTS |