Permit: T07CM04383

Parcel: 13317064B

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T07CM04383

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/04/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/25/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGES OK
09/22/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO CHANGE SINCE LAST INSP.
FLOOR SHALL SLOPE TOWARD DRAIN W/OUT LOW SPOTS
SEAL TO DRAIN FLANGE
ILLUSTRATIONS PROVIDED

CONTRACTOR TO PAY REINSPECTION FEE FOR FAILURE TO CORRECT PREVIOUSLY NOTED CORRECTIONS.

ALSO, CLOSET FLANGES ARE INSTALLED TO LOW
09/19/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
SLOPE SUB-FLOOR TOWARD DRAIN
SEAL TO LOWER DRAIN BODY
CHECK FOR CORRECT INSTALL PRIOR TO CALLING FOR INSPECTION
09/18/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. UTILIZE CLAMPING RING
MEMBRANE SHALL BE INSTALLED BETWEEN DRAIN FLANGES (CLAMPING RINGS)
2. REMOVE CONDENSATE DRAIN FROM SEWER CLEANOUT
PLUG CLEANOUT AND PROVIDE CORRECT CONNECTION, GIVEN ON TEMPORARY SITUATIONS.
08/13/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
P-7 DWV OK
PROVIDE FREE AIR SPACE FOR AAV
INSTALLED ABV CEILING CONTRARY TO PLAN
WATER PIPING IS PEX
PROVIDE APPROVAL OF MATERIAL TYPE FROM ENGINEER
IF NOT SPECIFIED ON PLAN
07/29/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WALLS OK
STILL NEED CLAMPS ABV CEILING AND NEED CLOSET FLANGES
07/28/2008 PLUMBING - INTERMEDIATE Cancelled PER MARIO RUIZ OF DIVERSIFIED
07/25/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
AT LEAST 4 SEPARATE LOCATIONS ARE MISSING SAFETY PLATES ON BOTH CU AND CI PIPING. ALL DRAIN PIPES MUST BE CAPPED DURING CONSTRUCTION TO PREVENT SEWER GASES FROM ESCAPING IN BUILDING
OVERHEAD PIPING NEEDS CLAMPS
LAST WARNING FOR REINSPECTION FEES
THIS APPLIES TO ALL PERMITS FOR THIS ADDRESS
07/23/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
DENIED INSP. MAY RESULT IN REFEE's
07/14/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NEED TO INSPECT INTERMEDIATE FOR STRAPPING
INSULATE AND FIXTURE ADD
06/23/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
06/20/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NEED TO SEE STRAPPING, ALSO CHANGES
SEE NOTES FROM 6/3
06/06/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CU W/90 PSI TEST
INSULATE, SECURE
06/03/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. DWV TEST OK
2. CONNECT VENTS ABV CEILING
HARD CAPS
3. STILL NEED TO SEE PIPE INSULATION, STRAPPING AND
FHA STRAPS
4. ALSO, SHOWER DIVERTER AND DRAIN
5. OK TO ONE SIDE
05/30/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO INSULATE WATER PIPING
04/11/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SOIL PIPE PER REDLINES, SW CORNER
OK TO COVER
04/10/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
TEST
REDLINES