Permit: T07CM04373

Parcel: 12404032B


Addresses:

1443 E 1ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/13/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
RECEIVED BACTERIA REPORT

BUILDING INSPECTOR TO RECEIVE (1) IN-HOUSE BACKFLOW CERTIFICATION

GAS CARD AT METER
08/11/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PROVIDE BACKFLOW CERTIFICATION, BACTERIA REPORT AND VACUUM BREAKER AT FRONT HOSE
08/08/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. MORE THAN 90 DEG. CHANGE OF DIRECTION ON A TRAP ARM REQUIRES A CLEANOUT
2. MORE THAN FIVE FEET ON INDIRECT WASTE REQUIRES A DIRECT TRAP
3. EACH WATER SUPPLIED EQUIPMENT TO HAVE BACKFLOW PROTECTION
CHECK AIR GAPS (GRATES, STRAINERS)
4. WILL NEED TO SEE PRESSURE TEST ON ENTIRE SYSTEM
ALSO, SAFETY CHECK ON EXISTING SYSTEM