Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM04358
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
04/30/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - OPEN FRONT TOILET SEAT AND TEMPERING VALVE REQUIRED IN NEW EMPLOYEE TOILET RM - CORRECT SLOPE ON BEV. DISP. DRAIN - PROVIDE BACKFLOW PROTECTION FOR NON-CARBONATED BEVERAGES, SEPARATE UPSTREAM OF CARBONATED WATER SUPPLY - SEPARATE ID WASTE PIPING - GRATES REQUIRED ON FS - PROVIDE 1" AG ON ID WASTE PIPING @ ICE MACHINE |