Permit: T07CM04347

Parcel: 14029051A

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T07CM04347

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/20/2008 BUILDING - FINAL Approved CORRECTIONS NOTED PREVIOUSLY TO BE ADDRESSED ON NEW TI PERMIT. THIS "SHELL" IS COMPLETE.
11/19/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1. E 1ST FLOOR RESTROOM MENS NEED GRAB BARS INSTALLED IN H/C STALL
2. 2ND FLOOR LOW GLASS PANELS LESS THAN 18" ABOVE FLOOR NEED TO BE TEMPERED GLASS (16 TOTAL)
3. H/C PARKING SPACE WEST OF NORTH ENTRY @ 3% CROSS GRADE
4. COMPLETE PLYWOOD TEMP STAIR GUARD PANELS @ ENTRY STAIRS
5. COMPLETE ELEC., MECH., AND PLUMBING FINALS
11/14/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
VIEWED GENERATOR PAD ENTRANCE
SPECIAL INSPECTION BY WESTERN TECH.