Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T07CM04347
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
08/04/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | OK TO POUR 4 - 4'3" WING WALLS AT BOX CULVERT SPECIAL INSPECTED WESTERN TECH. | |
07/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* TOP SLAB AT CULVERT |
|
07/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL 4 WALLS FOR BOX CULVERT DOES NOT INCLUDE WING WALLS 1. WESTERN TECH. SPECIAL INSPECTED |
|
07/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* BOX CULVERT BASE AND FOOTINGS OK TO POUR 1. WESTERN TECH. SPECIAL INSPECTED |
|
07/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO GROUT DOUBLE TRASH ENCLOSURE PROVIDE KNOCKOUTS AT BOTTOM CELLS |
|
05/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* DOUBLE TRASH ENCLOSURE FOOTING @ WEST SIDE |
|
05/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
05/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* LIGHT POLE CAISSONS MAINTAIN CLEARANCE 10 TOTAL OK TO POUR WITH SPECIAL INSPECTION |
|
04/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* #F-10 INGROUND FOOTING FOR NORTH END OF PANEL #P30 AS PER DETAIL #115 ON SHEET S6.1 |
|
04/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR F5 FOOTING AT 5.2 BETWEEN A & A.2 |
|
04/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR 6A, 29, 31, 30 SPECIAL INSPECTED |
|
04/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
04/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL 27, 25, 6, 5, PANELS 5 MISSING 21-A IMBED SPECIAL INSPECTED |
|
04/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR 4, 7, 8, 9, 10, 36, 37 PANELS SPECIAL INSPECTED RFI FOR 1 1/2 CLEARANCE |
|
04/01/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR PANELS 1, 21, 24, 13, 26, 32, 33 |
|
03/28/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR PANELS 15 & 16 SPECIAL INSPECTED |
|
03/27/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PANELS 2 & 3 |
|
03/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR PANELS 18A, 14 SPECIAL INSPECTED |
|
03/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* TILT PANELS 12, 19, 34A, 35 RFI #24 FOR BLOCK OUT DETAIL OK TO POUR |
|
03/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 20, 22, 23, 11 OK TO POUR WITH RFI HAS 3 TOP AND BOTTOM INSTEAD OF 1 MATT IN THE MIDDLE PER PLAN |
|
03/20/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 3-TILT WALL PANELS #17, 18 & 28 SPECIAL INSPECTION BY WESTERN TECH. |
|
03/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* #5 INSTEAD OF #4 DOWELS AT ELEVATOR STEM TO SLAB SPECIAL INSPECTED - NEEDS 24" LAP |
|
03/04/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTING GRID 6/D TO C.1 RFI #34 COLD JOINT SPECIAL INSPECTED |
|
03/03/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR ELEVATOR FOOTING SPECIAL INSPECTED WESTERN TECH |
|
02/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* NEEDS PANEL 30 FOOTING & ELEVATION WEST TECH SPECIAL ALSO, EXT. COLUMN FOOTINGS OK TO POUR A-1 TO 11, 1- A TO D, 11-A TO D, D-1TO 5 AND 6 TO 11 |
|
02/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR 21 INTERIOR SPREAD FOOTINGS NOT ELEVATOR PIT |
|
02/01/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INFORMATION |