Permit: T07CM04327

Parcel: 12801005H

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/29/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
04/28/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSTALL PER APPROVED PLAN, PROVIDE REDLINES ON SITE IF CHANGES ARE MADE, FAILURE TO COMPLY WILL RESULT IN REINSPECTION FEES.
04/24/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DWV TO 3' FROM ROOF WATER TEST OK
WATER PIPING RESTROOM & DF OK

1. INSTALL HOT & TEMPERED PIPING PER PLAN FOR MOP SINK AND TO REST OF PROJECT
04/11/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- KEEP ALL OPEN PIPES PLUGGED DURING
CONSTRUCTION 4" CO
- CORRECT BACKPITCH ON VENT AT LAVATORY
- SUPPORT HORIZONTAL PIPING
- DF WASTE & VENT IS OUT OF WALL
- WATER PIPING NOT PER PLAN; SIZE AT MS ALSO, INSTALL HAMMER ARRESTORS PER PLAN. TEMPERED WATER SHOWN TO ALL EXCEPT MS. MS FAUCET REQUIRES BACKING.