Permit: T07CM04316

Parcel: 137084720

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/29/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/16/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO COVER WALLS EXTERIOR
2) TRUSS A2 IN GARAGE NEED REPAIR DETAIL FOR NOTCHED TOP CHORD 2 X 4
04/15/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval 1) CHANGE OUT NAILS IN P.A.'S 16D SINKERS .148 DIAMETER NAILS REQUIRED OR 2 1/2" .162 TECOS
2) NO PLANS OR PERMIT ON SITE
3) CHECK GABLE MID SPAN AT GARAGE 2 X 4 TOP CHORD, OUTRIGGER NOTCHED NO WALL BELOW. CHECK CONTINOUS BEARING
4) ADD SHEAR TRANSFER 3 PLACES TWO FRONT AND ONE AT REAR