Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM04304
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/01/2008 | FRAMING | Approved | IVRS - Inspection :* | |
04/23/2008 | FRAMING | Partial Approval | IVRS - Inspection :* ENGINEERING - NEEDED FOR SHEAR PANEL ABOVE GARAGE AND STRAPPING OF BEAM AT CENTER OF HOUSE |
|
04/22/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* - DRAFT STOP IN FLOOR TRUSSES NOT COMPLETE - ENGINEERING FOR PLAN REVISIONS STAMPED BY CITY - FIRESTOP TRIANGULAR CHASE ABOVE 4-GANG BOX IN DINING ROOM |
|
04/21/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRAFT STOP FLOOR TRUSSES 1000 DIAMETER 2) HOLDOWNS IN KITCHEN SHEARWALL 3) NEED LETTER FOR CMST16 IN GARAGE CEILING 4) FIX STUCCO AROUND VENT SOUTH WALL 5) IS BOND CLAMP TO UFER A LISTED CLAMP FOR BRAIDED WIRE ? 6) HOLDOWN FOR SHEAR AT SOLE PLATE PER SHEAR PLAN MAIN FLOOR BATH 7) 4 KING STUDS NEEDED PER PLAN EACH END OF 16' OVERHEAD DOOR 8) LONGER NAILS OR REMOVE BLOCK AT END OF BEAM CENTER 9) STOPPED INSPECTION |