Permit: T07CM04296

Parcel: 13315305F

Inspection Status: Cancelled

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/11/2008 PLUMBING - INTERMEDIATE Cancelled PER SAM
08/01/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER PIPE SIZING NOT PER PLAN
NO REDLINES ON SITE
2ND LEVEL WC NOT SHOWN ON PLAN
WATER TEST DOWN ON SOUTH HALF DWV
PEX TOUCHING METAL
SLOPE ON LAV DRAIN
07/25/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE APPROVED PLANS
2. CHECK WATER PIPING SIZE
3. SECURE PEX AT RISER AND IN WALLS
4. CORRECT EXTERIOR SERVICE AND PROTECT FROM STUCCO
5. CLOSET FLANGES WILL BE INSPECTED AFTER FINISHED FLOOR PRIOR TO SETTING CLOSETS.
6. INSTALL PER UPC INSTALLATION STANDARDS AND CODE SECTIONS - 316.3.1, 316.3.2, 704.4.3, 704.4.5
06/16/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*