Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 06/13/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SLOPE PLANS OK |
|
| 06/12/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* BACKPITCH @ 4" WYE 1/8" MIN. ON 4" AND 1/4" MIN. AND 2" PROVIDE CITY APPROVED PLANS AND PERMITS |
|
| 04/03/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* TOILET RMS 106 & 107 PER DIAGRAM 5 MP2 |
|
| 04/01/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* APPROVED PLAN ON SITE FOR NORTH HALF ONLY PROVIDE 4" RISER FOR 2ND LEVEL AND FULL SIZE CLEANOUT AS REQUIRED & RETEST |
|
| 03/28/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* PROVIDE APPROVED PLANS ON SITE WITH TEST |