Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM04291
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* REINSPECTED PER LEERAY'S DIRECTIVE (REINSPECTION FEE WAIVED) PLUMBING FINAL OK EXTERIOR CLEANOUTS AROUND GREASE INTERCEPTOR HAVE NOT BEEN CUT DOWN. BLDG. INSP. TO CHECK |
|
02/05/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. ALL EXTERIOR CLEANOUTS TO BE CUT DOWN TO GRADE AND TERMINATED IN AN APPROVED MANNER 2. GAS LAMPS TO BE INSTALLED AND CONNECTED 3. INDIRECT WASTE PIPING OVER FIVE FEET TO BE DIRECTLY TRAPPED 803.0 CHANGES OF DIRECTION REQUIRE CLEANOUT NO SPLASHING SUPPORT OF I.W. PIPING 4. CLEANOUTS TO BE MADE ACCESSIBLE. CLEANOUTS UNDER A COVER PLATE SHALL BE COUNTER SUNK TAPPED PLUGS (LEAVE ALL COVERS OFF) 5. NO VALVES DOWNSTREAM OF AN AVB (TABLE 6-2) LOCATION OF ANSUL VALVE INTERLOCK 6. BACKFLOW PROTECTION FOR ICEMAKERS 7. HOOK UP/CONNECT ALL EQUIPMENT 8. CAULK ALL FIXTURES 9. WHERE DOES COOKING LINE HAND SINK DRAIN 10. REQUIRE 12" CLEARANCE IN FRONT OF CLEANOUT 707.10 11. STERILIZATION AND CLEAN BACTERIA REPORT 12. BACKFLOW CERTIFICATION |