Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07CM04291
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/23/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
02/20/2009 | ELECTRIC - FINAL | Partial Approval | LAST ITEM IS WATER CONDITIONING UNIT | |
02/19/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
02/19/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. PLEASE VERIFY LISTING & LABELING FOR WATER CONDITIONING EQUIPMENT 2. USE APPROVED EXTENDER RINGS - METAL NOT APPROVED 3. GROUND UNDER COUNTER FIXTURE BASES 4. BOXES MORE THAN 1/4" - 314.20 5. SHEETMETAL THREAD SCREWS NOT ALLOWED FOR GROUNDING 6. BREAKER NUMBERING TO MATCH PANEL SCHEDULES DIMMER PANELS ALL PREVIOUS ITEMS CORRECTED |
|
02/12/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* COOK ISLAND: 1) IDENTIFY EQUIPMENT GROUND CONDUCTOR SERVICE LINE: 1) PROTECT CONDUCTORS AT FITTING 2) VERIFY LISTING OF COKE DISPENSER ASSEMBLY |
|
02/11/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
02/09/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
02/06/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* BORDER NEON: 1. USE APPROVED TERMINATION PLATES 2. TIGHTEN LOOSE FITTINGS 3. MAINTAIN NEON TUBING SPACING 1/4" -- 600.41 4. SECURE FLEX CONDUIT WITH GTO CABLING 5. MAINTAIN GTO CLEARANCES 600.32 ROOF: FINISH ANTENNA WORK OK ROOF EXCEPT AS NOTED |
|
02/05/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. PANEL DIRECTORIES TO BE AS PER 408.4 2. FINISH KITCHEN GFI's 3. PLEASE VERIFY LISTING FOR LV LIGHTS AND TRANSFORMER TO BE ACCESSIBLE 4. MAKE UP NEW TRANSFORMER AS PER ARTICLE 600 ROOF: 1. TIGHTEN LOOSE FITTINGS 2. MAINTAIN WORKING CLEARANCES 110.26 3. MAKE UP NEON TRANSFORMERS PER ARTICLE 600 4. GTO CABLE TO BE IN RACEWAY TO TERMINATION PLATES |
|
02/03/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* KITCHEN: 1. BOXES MORE THAN 1/4" BOX TO SURFACE 314.20 2. USE APPROVED HARDWARE WITH DEVICES 3. KITCHEN RECEPTACLES TO BE GFI PROTECTED 210.8 4. FINISH SEALS ABOVE WALK-INS - 300.7 5. COLOR CODING FOR CONDUCTORS IN TUCSON AMENDMENTS ARE BLACK, RED, BLUE, 120/240V BROWN, ORANGE, YELLOW 277/480V |
|
01/28/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* |