Permit: T07CM04276

Parcel: 12106285A


Addresses:

1641 N SAHUARA AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/12/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/11/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OK TO COVER WALLS & FLOOR
2. FOAM WRAP ALL PIPING PASSING THRU CONCRETE
3. INSTALL BACKING & SAFETY PLATE AT LAV
4. RED LINE CHANGES AT WH CIRC. PUMP
5. RECALL FOR CLOSET FLANGE INSP.
07/08/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CORRECT BACK PITCH AT 2" SWEEP
2. PROVIDE FULL SIZE CLEANOUTS
3. PROVIDE PROPER DIRECTIONAL FITTINGS; COMBOS, SWEEPS
4. SECURE PIPING MID-STORY
5. INSTALL SAFETY PLATES
6. PROVIDE OWNERS OK FOR PEX
7. ISOLATE CO FROM METAL