Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 07/11/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER WALLS & FLOOR 2. FOAM WRAP ALL PIPING PASSING THRU CONCRETE 3. INSTALL BACKING & SAFETY PLATE AT LAV 4. RED LINE CHANGES AT WH CIRC. PUMP 5. RECALL FOR CLOSET FLANGE INSP. |
|
| 07/08/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CORRECT BACK PITCH AT 2" SWEEP 2. PROVIDE FULL SIZE CLEANOUTS 3. PROVIDE PROPER DIRECTIONAL FITTINGS; COMBOS, SWEEPS 4. SECURE PIPING MID-STORY 5. INSTALL SAFETY PLATES 6. PROVIDE OWNERS OK FOR PEX 7. ISOLATE CO FROM METAL |