Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM04228
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/06/2008 | PLUMBING - FINAL | Approved | ||
07/10/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* NEED AS BUILT APPROVAL |
|
07/08/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* NEED CITY APPROVED REVISION FOR ADDITIONAL HAND SINK |
|
07/07/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. APPROVED PLANS NOT ON SITE 2. ALSO, YOUR IRRIGATION ASSEMBLY IS TOO LOW AND IS MISSING THE UNION 3. THE HANDLE UPSTREAM OF DOMESTIC RP IS BURIED 4. MIXING OF DISSIMILAR METALS IS PROHIBITED IN NEW CONSTRUCTION IS GALVANIZED ALLOWED PER PLAN SPECIFICATIONS? |
|
07/01/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* AFTER HRS. CK #0608127759 - $150.00 RECEIVED BACTERIA REPORT FOR POTABLE WATER RECEIVED (7) IN HOUSE BACKFLOW CERTIFICATIONS 1. NEED COMPLETION & INSPECTION OF WATER HEATER VENT BY MECH. INSPECTOR BEFORE GAS IS ENERGIZED 2. NEED CITY APPROVED STAMPED REVISION FOR ADDITION OF HAND SINK PER PIMA COUNTY HEALTH GAS CARD TO GENERAL CONTRACTOR 1-480-214-3626 |
|
06/30/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE SEPARATE SOURCE OF WATER FOR CHEMICAL ADDITION AT 3-COMP SINK & JANITOR SINK 2. PROVIDE IN HOUSE BACKFLOW CERTIFICATIONS 3. PROVIDE SEPARATE FULL SIZE DRAINS FOR ICE MACHINE 4. SEPARATE T&P DRAIN FROM RP DRAIN 5. COMPLETE INSULATION AT WATER HEATER 6. COMPLETE VENTING FOR WATER HEATER 7. BACTERIA REPORT TO HAVE ADDRESS OF THIS JOB 8. PROVIDE CORRECT CRITICAL LEVEL AT URINAL 9. FLOOR DRAINS TO BE FLUSH TO FLOOR |