Inspection History Details
Inspection Status: Cancelled
Inspection History: PLUMBING - FINAL
Permit Number - T07CM04227
Inspection Description - PLUMBING - FINAL
Inspection Status - Cancelled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2008 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled | |
09/12/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
08/21/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE MEANS FOR WATER HAMMERING AT WASHER BOX 2. PROVIDE SUPPORT AND PRIMER & GLUE FOR PVC PIPING 3. COMPLETE INSTALL OF MOP SINK 4. COMPLETE LIST FROM 7/30/08 |
|
08/13/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* COMPLETE LIST FROM 7/30/08 |
|
07/30/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* COMPLY W/COT REQUIREMENTS FOR FOOT SPAS; HANDOUT PROVIDED 1. ANSI LISTING 2. DIRECT CONN FOR GRAVITY DRAINS ALSO, PVC PRIMER REQUIRED ON PVC JOINTS PROVIDE ACCESS OF RPA INDIRECT WASTE RECEPTORS PER 804.1 WHICH DOES NOT ALLOW RECEPTORS IN ANY PORTION OF THE BUILDING NOT IN GENERAL USE; COMMON WALL BETWEEN SUITES. ALSO, PROVIDE ACCESS PER 603.3 AND INSTALLATION STANDARDS. 4" NEEDED ABV HIGHEST TC UNIONS REQUIRED AT RPA's AND AT RP SUPPORT EXP. TANK AND RECIRC. PUMP CORRECT LEAK PROVIDE BACKFLOW CERTS AND BAC.T REPORT |