Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM04221
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/05/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* RECEIVED BACTERIA REPORT FOR POTABLE WATER RECEIVED (8) IN HOUSE BACKFLOW CERTIFICATIONS |
|
07/31/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE BACKFLOW PROTECTION FOR TEA BREWER WITH CERTIFICATION 2. PROVIDE BACTERIA REPORT FOR POTABLE WATER |
|
07/24/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE CLEAN BACTERIA REPORT 2. PROVIDE ACCESS PANEL FOR TRAP PRIMERS & SHOCK STOPS AS REQUIRED 3. PROVIDE ACCESS TO ALL CLEANOUTS WITH FACTORY TAPPED PLUGS AND MACHINE SCREWS FOR CLEANOUT COVERS 4. PROVIDE 6" MINIMUM CRITICAL LEVEL AT URINAL FLUSH VALVE 5. PROVIDE BACKFLOW CERTIFICATIONS FOR ALL IN HOUSE DEVICES 6. PROVIDE BACKFLOW DEVICE FOR MOP SINK CHEMICAL ADDITION PER PLAN NOTE #13 PAGE P.2 7. PROVIDE CORRECT BACKFLOW PROTECTION FOR CHEMICAL ADDITION AT DISHWASHER AREA 8. PROVIDE ALL OWNER PLUMBING DEVICES INSTALLED CORRECTLY 9. SEE PLAN NOTES PAGE P.2 FOR BACKFLOW DEVICES REQUIRED 10. PROVIDE CORRECT LONG RADIUS DRAINAGE FITTINGS AT ALL 3-COMP SINKS, AT SPRAY TABLE FOR DISHWASHER AND PROVIDE 1" MINIMUM AIR GAP FOR SPRAY HANDLE AT SPRAY TABLE. 11. PAINT VENT THRU ROOF 12. INSULATE WATER PIPING ON ROOF SUBJECT TO FREEZING 13. FLOOR DRAINS TO BE FLUSH WITH FLOOR 14. FLOOR SINKS TO HAVE GRATES LIST NOT COMPLETE |
|
07/23/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* YOU NEED TO CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS BEFORE YOU RECALL THE FINAL CONTINUED "NOT READY" WILL RESULT IN REINSPECTION FEE |