Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2008 | FRAMING | Approved | IVRS - Inspection :* | |
02/14/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROPER STRAP NEEDED AT PLATE KITCHEN BEARING WALL 2) BEARING NEEDED UNDER OVERHEAD GARAGE WING WALLS 3) BEAM AT STRIRWAY NEED 3-2 X 6'S AB TRIMMERS 4) BEARING OF TOP FLANGE OF FLOOR TRUSSES 5) GROUND RODS |