Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM04195
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
01/24/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED HANGER FOR TRUSS GIRDER AT RAFTERS 2ND FLOOR |
|
01/23/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 502 SHEAR DETAIL ON GARAGE WALL 2) ANCHOR BOLTS AND HOLDOWNS THRU-OUT 3) STRAP BELLY BAND NORTH SIDE 4) RAFTER SHORT OF BEARING WALL 2ND FLOOR WEST SIDE OF HOUSE 5) STRAP DBL PLATES 2ND FLOOR |