Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM04191
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/21/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/21/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) HOLDOWNS AND INTERIOR BOLTS LOOK AT INTERMEDIATES |
|
04/18/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RETRO'S NEEDED FOR OVER SPALLED HOLDOWN AT GARAGE FRONT (2 OF THEM) 2) WEST SIDE BELLY BAND NEEDS NAILS INFO 2ND FLOOR BOTTOM PLATE AND EAST SIDE 3) NAIL HOLDDOWN (MAS) WEST SIDE 4) INSTALL INTERIOR HOLDOWNS AND ANCHORS 5) NAIL PLATE PROTECTION ON SILL PLATES |