Permit: T07CM04175

Parcel: 140132480


Addresses:

2132 E BALSAM CI

Inspection Status: Denied

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
05/30/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CERTIFY REINFORCEMENTS IN CMU WALL AND COLUMNS COMPLY WITH DRAWINGS
2) FRAMING MEMBER SIZES DO NOT COMPLY WITH EXISITNG DRAWINGS
3) EXPOSE CONNECTION BETWEEN CMU AND 4 X 8 BEAM ON WALL
4) 2 X FASCIA SHALL NOT BE USED AS BEAM
5) EXPOSE FRAMING TO VERIFY TREATED PLATES AND CONNECTIONS AT EXTERIOR FURR OUT WALLS
6) EXPOSE FOUNDATION FOR CMU COL. AND CMU WALL FOR INSPECTION
7) KITCHEN CABINETS SHALL BE INSTALLED PROR TO FINAL