Permit: T07CM04150

Parcel: 140130380

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/06/2008 FRAMING Approved IVRS - Inspection :*
02/21/2008 FRAMING Partial Approval IVRS - Inspection :*
1) NEED ONE GAS BOND, ON H20 BOND EXPOSED
2) BANG PLATE DRYER DUCT
3) NEED GAS PRESSURE TEST
4) ALL DUCT TO BE INSULATED MIN R-8 INSUL
5) PROTECT JOINT SIDING EXT PLATE JOINT TO CONCRETE
6) H20 TEST OK, NEED GAS
7) BOTH ROMEX TO ROOF SECURE AWAY FROM SHARP EDGE OF CONDUIT, THRU ROOF
8) VERIFY HEAT PUMP AMPS, 5 OPTIONS ON U.L. LABEL
9) OK TO COVER ONE SIDE OF WALLS
12/18/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL OTHER TRADES PRIOR TO FRAME APPROVAL