Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07CM04121
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2007 | ELECTRIC - FINAL | Approved | PER INSP CARD | |
11/13/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROPERLY MOUNT SMOKE DETECTORS 2) PROVIDE GFI PROTECTION FOR KITCHEN COUNTER RECEPTACLES |
|
11/06/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CALL WHEN METER 336 & 340 ARE ENERGIZED |
|
11/01/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ROOFTOP EQUIPMENT TO BE LABELED BY MEANS SUITABLE FOR THE ENVIRONMENT, NOT SHARPIE 2. IDENTIFY "SERVICE DISCONNECTS" AS SUCH AND INSTALL ADDRESSES ON METER BASES 3. INSTALL SMOKE DETECTORS PER MANUFACTURES INSTRUCTIONS 4. CALL BOTH IN @ SAME TIME |
|
10/25/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PARTIAL INSPECTION ONLY 1. ALL (NEW) WIRING AND EQUIPMENT TO BE EXPOSED FOR INSPECTION - OPEN WALLS & CEILINGS AS NEEDED ON ROOFTOP 1. IDENTIFY NEW UNITS, DISCONNECTS AND PANEL DIRECTORY 2. IDENTIFY WHITE USED AS HOT 3. INSTALL PROPERLY SIZED FUSES 4. NEED ROOFTOP SERVICE GFI RECEPTACLE 5. IDENTIFY UNITS DATA PLATES 6. SECURE RACEWAYS TO ROOF 7. DISCONNECT NOT TO HAVE DRAIN PIPE IN FRONT OF IT |