Permit: T07CM04114

Parcel: 11004345J


Addresses:

3225 N SWAN RD #111

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/19/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/13/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
OK TO BACKFILL W/CLEAN DIRT
NO ROCKS
RECALL FOR PRE-SLAB INSPECTION
02/12/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE THE MIN. 1/4" PER FOOT SLOPE
PROVIDE MIN. TRAP ARM DISTANCE AT MS
REMOVE ROCKS FROM AROUND PIPE